听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览PHYSICS IN MEDICINE AND BIOLOGY期刊下所有文献
  • Computed temperature distributions around ectatic capillaries exposed to yellow (578 nm) laser light.

    abstract::We have numerically modelled the thermal effects of yellow (577 or 578 nm) light illumination on the ectatic blood vessels of port wine stains. We investigated the effect of the laser treatment parameters of light irradiance and illumination time on the extent of coagulation (coagulation thickness) of the endothelial ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/9/010

    authors: Pickering JW,Butler PH,Ring BJ,Walker EP

    更新日期:1989-09-01 00:00:00

  • Examination of errors caused by random summing in in vivo prompt gamma ray analysis.

    abstract::A technique is described for examining the mode of operation of radiation detectors and estimating the losses and gains caused by random summing effects in spectra acquired at high counting rates. The technique is applied to estimating the errors caused by random summing when measuring the amounts of carbon and nitrog...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/8/010

    authors: Yankuba S,Oldroyd B,Metcalfe SC,Godfrey JE,Oxby CB

    更新日期:1989-08-01 00:00:00

  • The quality of ionising radiations emitted by radionuclides incorporated into mammalian cells.

    abstract::Radionuclides which decay by electron capture accompanied by Auger electron cascades, or by beta emission are thought to be excessively damaging when incorporated into the molecular structure of mammalian cell nuclei and thereby pose a radiation hazard which is not assessable by conventional dosimetry. Survival data, ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/7/003

    authors: Younis AR,Watt DE

    更新日期:1989-07-01 00:00:00

  • Comparison of in vivo scintillation probes and gamma cameras for detection of small, deep tumours.

    abstract::An in vivo probe was compared with a gamma camera for the task of detecting radiolabelled tumour models in a water phantom. The probe, which contained a 1 cm diameter NaI(T1) detector, was designed and used by us for surgical staging studies of gynaecological patients. Tumours were spherical sources of different sizes...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/6/008

    authors: Barber HB,Barrett HH,Woolfenden JM,Myers KJ,Hickernell TS

    更新日期:1989-06-01 00:00:00

  • Radiation dose factors for alpha-emitters in osteons and some considerations on dose non-uniformity ratios and relative distribution factors.

    abstract::Dose factors for locations within a tissue-filled cylindrical cavity bounded by an infinite medium of bone labelled with an alpha-emitter are calculated by means of a Monte Carlo procedure. The calculational approach is general and allows us to determine dose factors for specific distances or target volumes defined by...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/3/007

    authors: Polig E

    更新日期:1989-03-01 00:00:00

  • Effective energy resolution and scatter rejection in nuclear medicine.

    abstract::All available imaging devices in nuclear medicine have finite energy resolution. This leads to inclusion of scattered radiation, which in turn degrades the image quality. Different scatter correction schemes therefore try to eliminate the effect of scattered radiation. On the other hand, improvement of the camera's in...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/34/1/008

    authors: Wirth V

    更新日期:1989-01-01 00:00:00

  • Infrared and visible thermoluminescence signals of Tm-doped CaF2 measured by a semiconductor photodiode.

    abstract::A silicon semiconductor photodiode was used to measure the TL-signal of TLD-300 (CaF2:Tm) detectors irradiated with 60Co gamma rays and 226Ra alpha particles. The applied dose values varied from 0.12 to 14.3 Gy for gamma rays and from about 50 to 300 Gy for alpha particles. Because of the infrared sensitivity of the p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/12/006

    authors: Meissner P,Jacob M,Rassow J

    更新日期:1988-12-01 00:00:00

  • On the possibility of obtaining non-diffused proximity functions from cloud-chamber data: I. Fourier deconvolution.

    abstract::A mathematical procedure, using Fourier deconvolution, is described whereby diffusion-free proximity functions can be obtained from cloud-chamber data. Such non-diffused distributions can be used to obtain further microdosimetric and nanodosimetric quantities hitherto not available from experiments, thus making the cl...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/11/004

    authors: Zaider M,Minerbo GN

    更新日期:1988-11-01 00:00:00

  • Neutron scattering cross sections and partial kerma values for oxygen, nitrogen and calcium at 18 less than En less than 60 MeV.

    abstract::Recent measurements of differential elastic and inelastic neutron scattering from oxygen, nitrogen and calcium at 18 less than En less than 26 MeV are presented and analysed in terms of the optical model. These data, together with earlier measurements of scattering and total cross sections, are used to construct model...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/33/3/001

    authors: Islam MS,Finlay RW,Petler JS,Rapaport J,Alarcon R,Wierzbicki J

    更新日期:1988-03-01 00:00:00

  • Scatter dose for wedged fields.

    abstract::The behaviour of scatter dose in 4 and 8 MV wedged x-ray beams has been studied by calculating scatter-to-primary dose ratios (SPR) and comparing these with SPR for non-wedged beams. On the central axis the SPR for wedged and non-wedged beams differ only by a few per cent, a difference which increases slightly with we...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/010

    authors: Brown LH,Siddon RL,Bjärngard BE

    更新日期:1987-10-01 00:00:00

  • Isotope computed tomography using cone-beam geometry: a comparison of two reconstruction algorithms.

    abstract::A CT scanner has been constructed specifically to determine the three-dimensional distribution of bone mineral in the medullary cavities of the radius, ulna and femur. A source of x-rays (153Gd) and a multiwire proportional counter (MWPC) are mounted at opposite ends of a diameter of an annular mounting. The limb is p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/10/002

    authors: Horsman A,Sutcliffe J,Burkinshaw L,Wild P,Skilling J,Webb S

    更新日期:1987-10-01 00:00:00

  • Intensity of the flash associated with laser-induced plasma in the eye.

    abstract::A bright flash of light is emitted by the plasma formed at the focus of an ophthalmic Nd: YAG laser. The purpose of this investigation is to determine whether the plasma flash constitutes a hazard to the operator. The intensity of the flash at the slit lamp eyepiece was measured and the experimentally derived value wa...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/9/009

    authors: Moseley H,Allan D

    更新日期:1987-09-01 00:00:00

  • Influence of the physical state and straggling on the computation of the radiation dose due to radon daughters deposited in the lung.

    abstract::The effect of the physical state (phase) of the absorbing medium and the energy straggling of the alpha particles on the calculation of the radiation dose due to the daughter products of radon deposited in the lung have been studied in detail. The stopping power data for alpha particles in water and water vapour have ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/8/004

    authors: Haque AK,Al-affan IA

    更新日期:1987-08-01 00:00:00

  • Dynamics of the upper urinary tract: I. Peristaltic flow through a distensible tube of limited length.

    abstract::A theoretical analysis and numerical solutions are presented for viscosity-dominated flow through a uniform, highly distensible tube with a slit-shaped cross section undergoing peristalsis. At flow rates below an intrinsic upper limit to the peristaltic carrying capacity of the tube, provided that there is always at l...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/7/002

    authors: Griffiths DJ

    更新日期:1987-07-01 00:00:00

  • The noise power spectrum of CT images.

    abstract::An expression for the noise power spectrum of images reconstructed by the discrete filtered backprojection algorithm has been derived. The formulation explicitly includes sampling within the projections, angular sampling, and the two-dimensional sampling implicit in the discrete representation of the image. The effect...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/5/003

    authors: Kijewski MF,Judy PF

    更新日期:1987-05-01 00:00:00

  • Stopping power and ranges of low-energy protons in tissue-equivalent gas.

    abstract::Stopping power data for protons in tissue-equivalent gas (64.4% CH4 + 32.4% CO2 + 3.2% N2, partial pressures) were derived from experimentally determined ranges and from differential ionisation distributions using the differential energy required per ion pair formed to convert ionisation to energy loss. The proton ene...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/3/006

    authors: Waibel E,Willems G

    更新日期:1987-03-01 00:00:00

  • Modelling the temporal region in patients with temporal lobe epilepsy.

    abstract::EEG interictal epileptiform discharges in temporal lobe epilepsy are associated with magnetic fields. The maxima of magnetic spikes recorded over the spherical portions of the head appear fairly symmetric, whereas those over the lower temporal region often have irregular shapes. Furthermore, their magnitude is often u...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/009

    authors: Rose DF,Sato S,Smith PD,White J

    更新日期:1987-01-01 00:00:00

  • Improved procedure for neuromagnetic localisation.

    abstract::We describe an improved algorithm for localising equivalent sources of biomagnetic fields in the human brain. The algorithm is an improvement over the sphere model in that it considers two distinct surfaces: an ellipsoid, to model the region of the skull on which the sensors are placed, and a sphere as the medium in w...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/32/1/017

    authors: Pistella F,Barone P,Narici L,Ocello N,Pizzella V,Romani GL

    更新日期:1987-01-01 00:00:00

  • Aluminum equivalence of materials used in diagnostic radiology and its dependence on beam quality.

    abstract::A semi-empirical theory has been derived that relates the aluminum equivalence of various materials used in diagnostic radiology to their attenuation coefficients. The dependence of the aluminum hardness (AHE) and attenuation (AAE) equivalent on the beam quality is described in terms of effective energy. This 'aluminu...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/12/006

    authors: Nagel HD

    更新日期:1986-12-01 00:00:00

  • The modelling of biological systems in three dimensions using the time domain finite-difference method: I. The implementation of the model.

    abstract::A computer method has been developed which uses the time domain finite-difference (TDFD) algorithm to calculate the deposition of the electromagnetic (EM) field in three-dimensional biological models. This, the first of two papers, describes the algorithm and the computer programs developed. The method is demonstrated...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/11/006

    authors: Lau RW,Sheppard RJ

    更新日期:1986-11-01 00:00:00

  • A multiplicative correction factor for tissue heterogeneities.

    abstract::A new multiplicative correction factor for tissue heterogeneities based on an exact expression for homogeneous non-unit-density media is proposed. O'Connor's density scaling theorem is invoked to evaluate the medium-specific tissue-maximum ratios used in the exact formulation. Monte Carlo calculations were performed a...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/10/005

    authors: Petti PL,Siddon RL,Bjärngard BE

    更新日期:1986-10-01 00:00:00

  • Numerical considerations for interface reflections in medical ultrasound.

    abstract::The original concept of the echo mechanism in diagnostic medical ultrasound--of step impedance discontinuities--is investigated in terms of the numerical implications of more refined models. The effect of a discontinuity in the attenuation coefficients is found to have as much significance as the impedance discontinui...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/001

    authors: Chivers RC,Santosa F

    更新日期:1986-08-01 00:00:00

  • In vivo and in vitro dielectric properties of feline tissues at low radiofrequencies.

    abstract::The dielectric constant and conductivity of muscle, liver, spleen and kidney of cats in vivo and in situ immediately following the animal's death were measured at frequencies from 10 kHz to 100 MHz. A novel multi-ring capacitive sensor and a computer-controlled automatic network analyser (ANA) were employed. The resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/8/007

    authors: Surowiec A,Stuchly SS,Keaney M,Swarup A

    更新日期:1986-08-01 00:00:00

  • Generalised use of contrast degradation and contrast improvement factors in diagnostic radiology. Application to vanishing contrast.

    abstract::Although field area and object thickness are important parameters in comparisons of techniques for optimal reduction of scattered radiation to the image, they are in practice seldom varied. For this reason, we suggest that contrast degradation (CDF) and contrast improvement (CIF) factors be more frequently used and ap...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/7/004

    authors: Carlsson GA,Carlsson CA,Nielsen B,Persliden J

    更新日期:1986-07-01 00:00:00

  • Filter materials for dose reduction in screen-film radiography.

    abstract::A computer program was developed to calculate both integral absorbed dose in a water phantom and entrance exposure, for the imaging of iodine contrast with x-ray intensifying screens. The effect of filtration of the x-ray beam on integral absorbed dose and entrance exposure was studied for 27 different filter material...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/6/001

    authors: Koedooder K,Venema HW

    更新日期:1986-06-01 00:00:00

  • Comparison of recent codes of practice for high-energy photon dosimetry.

    abstract::Absorbed dose values were determined under the reference conditions in a phantom irradiated by high-energy photon beams with quality varying between 60Co gamma rays and 25 MV X-rays, using four commonly employed types of ionisation chamber. The ionisation chamber readings were converted to absorbed dose values applyin...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/006

    authors: Mijnheer BJ,Wittkämper FW

    更新日期:1986-04-01 00:00:00

  • A water calorimeter for neutron dosimetry.

    abstract::A water calorimeter has been used for the direct measurement of absorbed dose to water in a d(15) + Be neutron beam. The absorbed dose measured with the calorimeter was compared with that measured with an Exradin ionisation chamber, constructed of A-150 plastic. The doses measured by the ionisation chamber were calcul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/31/4/005

    authors: Galloway G,Greening JR,Williams JR

    更新日期:1986-04-01 00:00:00

  • The induction of hyperthermia by ultrasound; its value and associated problems: II. Scanned-plane transducer.

    abstract::A system is described in which large superficial areas of tissue may be heated using a single plane ultrasonic transducer scanned in a raster fashion. The shape of the heated area is determined by the movement of a microswitch which is activated when it strikes the rigid edge of a hole of the required shape cut in a p...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/12/006

    authors: ter Haar G,Hopewell JW

    更新日期:1985-12-01 00:00:00

  • W value measurements for protons in tissue-equivalent gas and its constituent gases.

    abstract::Values of W (the mean energy required to create an ion pair when a charged particle is stopped in a gas) are needed in radiation dosimetry to convert ionisation chamber current readings to absorbed dose. For neutron dosimetry the most important W values are those for protons, and this paper describes absolute measurem...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/11/003

    authors: Thomas DJ,Burke M

    更新日期:1985-11-01 00:00:00

  • Calculation of turnover rates in stable-isotope studies.

    abstract::Tserng and Kalhan have raised the question of the appropriate equation to use for the measurement of turnover rate in a stable-isotope study. In a comparison of glucose turnover measured with 2H-glucose and with 13C-glucose they used five apparently different equations and obtained conflicting answers. There is, howev...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/013

    authors: Wootton R,Ford GC,Cheng KN,Halliday D

    更新日期:1985-10-01 00:00:00

  • Dosimetry comparison and characterisation of an Al K ultrasoft x-ray beam from an MRC cold-cathode source.

    abstract::Ultrasoft x-rays of 0.3-5 keV have provided a unique tool for the investigation of intracellular mechanisms of radiation action in biological organisms, including mammalian cells. However, their use presents unique practical problems in dosimetry and experimental design. Detailed interpretation of the biological resul...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/10/002

    authors: Hoshi M,Goodhead DT,Brenner DJ,Bance DA,Chmielewski JJ,Paciotti MA,Bradbury JN

    更新日期:1985-10-01 00:00:00

  • Dielectric properties of ocular tissues in the supercooled and frozen states.

    abstract::Values of the relative permittivity and conductivity of the rabbit retina and lens have been measured between 10 MHz and 10 GHz over the temperature range 20 to -20 degrees C. As the temperature was lowered from 20 degrees C the dielectric parameters changed smoothly until -9 degrees C where freezing occurred. At this...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/9/009

    authors: Gabriel C,Grant EH

    更新日期:1985-09-01 00:00:00

  • Iterative deblurring algorithm for a multiplane tomographic scanner.

    abstract::An iterative algorithm has been developed to reduce blur artefacts in images obtained from the Pho/Con multiplane tomographic scanner. In this technique estimates of the activity distribution are convolved with the detector response function and compared with the original blurred image planes. Successive estimates of ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/7/004

    authors: Zenari A,Hooper RH,Osborne N,Scrimger JW

    更新日期:1985-07-01 00:00:00

  • Dead time correction and counting statistics for positron tomography.

    abstract::A correction for loss of events due to dead time in dynamic positron emission tomography (PET) is presented. The model employs a paralysing dead time to describe the behaviour of a tomograph over the range of event rates normally encountered in patient studies (up to 200 000 events/s per detector layer). The Donner 28...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/5/002

    authors: Mazoyer BM,Roos MS,Huesman RH

    更新日期:1985-05-01 00:00:00

  • The physics of red cell sedimentation.

    abstract::Blood was withdrawn from the ante-cubital vein of five normal volunteers and the erythrocytes were washed and resuspended in isotonic saline. The rate of descent of the erythrocyte-saline boundary was measured every hour for a period of at least 4 h for different suspended cell concentrations. The velocity of this bou...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/30/2/002

    authors: Smallwood RH,Tindale WB,Trowbridge EA

    更新日期:1985-02-01 00:00:00

  • Response of x-ray intensifying screens to scattered and primary radiation.

    abstract::The energy dependence of the luminance ratio due to scattered and primary radiation has been determined for four types of X-ray intensifying screens. A water phantom of 30 cm X 30 cm X 20 cm was used as the scattering medium. Ten narrow band X-ray spectra were used as incident radiation: the mean energies of these spe...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/007

    authors: Koedooder K,Venema HW

    更新日期:1984-10-01 00:00:00

  • Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigation.

    abstract::Energy and spatial projection distributions were simulated for gamma camera imaging of multiple order Compton scattered photons. SPECT imaging of a line source of radioactivity located in a water filled cylindrical phantom was modelled using Monte Carlo techniques. Photon trajectories were followed from emission to de...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/10/005

    authors: Floyd CE,Jaszczak RJ,Harris CC,Coleman RE

    更新日期:1984-10-01 00:00:00

  • Aerosol particle impaction in the conducting airways.

    abstract::Modelling of inhaled particle deposition in the lungs potentially offers data relevant to assessing hazards from toxic inhaled particles, to studying mucus clearance or lung permeability by aerosol techniques, and to achieving better utilisation of drugs administered as aerosols. Analysis of published modelling studie...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/7/001

    authors: Agnew JE,Pavia D,Clarke SW

    更新日期:1984-07-01 00:00:00

  • Hysteresis heating for the treatment of tumours.

    abstract::A method is described whereby, utilising a biocompatible magnetic glass-ceramic material, effective hysteresis heating in living tissue was accomplished. Initial experiments on mice showed that a significant heating effect can be obtained in the ceramic-impregnated regions. An analysis is also given for the projected ...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/001

    authors: Borrelli NF,Luderer AA,Panzarino JN

    更新日期:1984-05-01 00:00:00

  • Dielectric studies on the reaction of the intracellular matter of fish red blood cells to detergent toxicity.

    abstract::Results from dielectric studies on the freshwater fish Cyprinus carpio exposed to a sublethal concentration of sodium alkyl benzene sulphonate were compared with those from untreated control fish; recovery from the test solution was also checked. The influence of the anionic detergent on the intracellular matter of fi...

    journal_title:Physics in medicine and biology

    pub_type: 杂志文章

    doi:10.1088/0031-9155/29/5/005

    authors: Bielinska I,Terlecki J

    更新日期:1984-05-01 00:00:00

1302 条记录 31/33 页 « 12...252627282930313233 »